REPLACEMENT SELENIUM SURGE SUPPRESSOR SPECIALIST
We are REPLACEMENT Rectifier Specialists
We are OBSOLETE Rectifier Specialists
We are URGENT Rectifier Specialists
How can we help?
Power Rectification Specialist, since 1945
CEHCO is the manufacturer, re-seller, and distributor of Power Rectification products such as DC Rectifiers, Transformer Rectifier Assemblies, and Custom Power Supplies since 1945.
Our division L/C Magnetics Inc. (www.lcmagnetics.com) builds transformer products from 0.1 KVA to 100 MVA. All CEHCO transformers are built by L/C Magnetics Inc.
CEHCO is a repair and replacement specialist for obsolete and discontinued DC Rectifiers.
Send us an email for a Free Quote.
quote@cehco.com
Our engineers will respond within the hour.
ABOUT SELENIUM SURGE SUPPRESSOR
Surge suppressors are used to protecting circuits from transients (sudden, brief increases in voltage). Transients of widely varying magnitudes are caused by such circuit components as motors, coils, magnets, relays, and transformers. They are found in all electrical systems and are notorious for damaging diodes, SCRs, transformers, triacs, and relay contacts.
Surge suppressors can be connected across individual components, part of a circuit, or to supply to an entire circuit. When the voltage is normal, they are in an “off” state and do nothing. However, when a transient raises the voltage, they react very quickly and conduct the excess around the components they protect. When the transient has passed they return to a normal “off” state. It is cheaper to use surge suppressors than it is to buy new components or have equipment out of service. Surge suppressors can be polar (for direct current circuits) or non-polar (for alternating current circuits) and can be assembled in different configurations to offer surge protection from 3A to 130A.
CEHCO surge suppressors are assembled from high-quality selenium cells. We are a selenium surge suppressor replacement specialist. These suppressors are characterized by extremely smooth operation. They pass increasing amounts of current as the voltage increases without the sudden changes that tend to characterize other types of surge suppressors. They have a high shunt capacitance (0.05 MFD per square inch). They react faster and have higher wattage capability than silicon suppressors. Selenium Surge Suppressors are commonly used in the elevator industry. CEHCO has done many applications for elevators and elevator companies. A brief description of selenium cells is shown below.
Click the links for further details:
We keep all materials (i.e. diodes, SCR’s, heat sinks, etc.) in stock for immediate assembly. To discuss your specific rectifier stack requirements, please contact us at 714 624-4740, or send us an email at quote@cehco.com.
Selenium Rectifiers & Suppressors, SELENIUM SURGE SUPPRESSORS, The Advantages of Selenium in Surge Suppression, Darrah Selenium Suppressors, Selenium Transient Voltage Suppressors, Surge Suppressors for the Protection of Solid-State Devices, Surge suppressors and clamps, Selenium Surge Suppressor Rectifier, Replacement Selenium Surge Suppressor, High Performance Surge Suppression, Industrial Grade Surge Protector, Custom Selenium Surge Suppression, Reliable Surge Suppressor Replacement, Efficient Surge Suppression Solution, Heavy-Duty Surge Protection, Compact Surge Suppressor Replacement, Durable Selenium Surge Suppressor, Advanced Surge Suppression Technology, Precision Surge Protection, Selenium Surge Suppressor Assembly, Low Maintenance Surge Protector, High Voltage Surge Suppressor Replacement, Robust Selenium Surge Suppressor, Customizable Surge Suppression Solutions, Versatile Selenium Surge Suppressor, Selenium Surge Suppressor Module, Efficient Surge Suppression System, Reliable Surge Suppression Unit, Replacement Selenium Surge Suppressor Specialists, Surge Protective Devices, Selenium Rectifier Replacement, The Advantages of Selenium in Surge Suppression Circuits, Replacement Selenium Surge Suppressor services offered, Replacement Selenium Surge Suppressor design considerations, Replacement Selenium Surge Suppressor troubleshooting techniques, Replacement Selenium Surge Suppressor performance assessments, Replacement Selenium Surge Suppressor safety standards, Replacement Selenium Surge Suppressor installation guidelines, Replacement Selenium Surge Suppressor user manuals, Replacement Selenium Surge Suppressor maintenance practices, Replacement Selenium Surge Suppressor applications in vintage electronics, Replacement Selenium Surge Suppressor customer reviews and feedback, Replacement Selenium Surge Suppressor cost considerations, Replacement Selenium Surge Suppressor impact on equipment longevity, Replacement Selenium Surge Suppressor in power distribution systems, Replacement Selenium Surge Suppressor environmental considerations, Replacement Selenium Surge Suppressor effectiveness in voltage spike protection, Replacement Selenium Surge Suppressor integration with modern systems, Replacement Selenium Surge Suppressor historical significance in surge protection, Replacement Selenium Surge Suppressor alternatives and recommendations, Replacement Selenium Surge Suppressor consulting services, Replacement Selenium Surge Suppressor reliability assessments, Replacement Selenium Surge Suppressor training and support, Replacement Selenium Surge Suppressor comparison with contemporary surge suppressors